It is a fact that a failure in power can lead to massive losses because of downtime. One recent research has revealed that a vast majority of power outages will last approximately 10 seconds or even less. However, these few seconds can cause plenty of damage in the long run. As a matter of fact, there will be a loss of approximately $5,600 for one minute of inactivity. Consequently, companies tend to invest their cash in systems that will guarantee them of ensuring the continuity of the infrastructures. One can consider the data center rack load bank to be a vital element for verifying and making sure that the continuity is maintained all the while. These are responsible for simulating different electrical conditions within a data center and verifying its resilience via different situations.
In this blog, we have mentioned why it will be sensible to make use of a data center rack load bank at present.
What do you mean by load banks?
You will come across lots of electrical parts in contemporary data centers. It is the proper functioning of these digital infrastructures that figure out whether they will be available or not. Load banks happen to be systems responsible for verifying, monitoring, and testing power supplies within a data center. The primary objective is to minimize downtime and facilitate effective operation in the long run.
They perform the testing of electrical systems for getting the job done, and this subjects them to stress tests for identifying prospective breakdowns, glitches, and insufficient loads. Here, the primary benefit is that it is possible to verify the power systems along with the power without interrupting any crucial loads. The continuity of service isn’t compromised which can be considered to be its benefit, and it is also feasible to identify vulnerabilities in the system plus optimize the lifecycle of components like UPS batteries or diesel engines.
The following systems are primarily employed for this type of usage in a typical data center out there:
• Maintenance
• Commissioning
• Replacement of components
• UPS systems testing
• Periodic verifications of standby generators
• Rack in servers
• Commissioning and startup of integration, heating, plus HVAC systems
It is possible for a data center rack load bank to be permanently installed or portable and one can purchase or even rent them for some particular operations or for performing verification testing before the authorizing of data center facilities.
Testing and commissioning of load banks
The commissioning phase happens to be one of the most significant applications for which we specifically recommend load bank testing at present. In this particular phase, we’re going to verify every component and system of a data center, and we likewise confirm that they have been properly set up as per the specifications demanded by the end-user.
Nevertheless, the issue here is that it is not possible to get hold of the actual load in the preliminary phases of a data center. This is because they make plans to expand slowly over time while adapting the consumption of power to the data center’s expansion. In these situations, the data center rack load bank will be the most effective way to perform a load bank heat simulation in a practical manner while ensuring the safety and security of each component.
Apart from being appropriate for simulating authentic power supply conditions, it is likewise ideal for the entire process of verification. You will come across many crucial elements for validation, and you should not take anything for granted right now.
Data center rack load bank for commissioning the cooling systems
It is possible to verify, regulate, and test a data center’s cooling systems during the later phases of commissioning along with assessing the performance and efficiency of air conditioning systems set up in the data center before operating it.
Load banks will help to figure out the following:
• Whether the cooling system happens to be well-sized
• If the standby equipment functions effectively if there is an increase in temperature or malfunctioning of other equipment
• Whether there is a proper distribution of the airflow
In this way, we can likewise test the proper configuration plus thermal jumps between the cold and hot aisles, figure out the recirculation, and adjust the cooling system’s flow of air.
Data center rack load bank monitoring
It is feasible to regulate each parameter required for making decisions, verifying, and assessing performance and efficiency with the help of intelligent load banks before using IT equipment for putting the data center rack into service.
It is possible for these load banks to record the consumption of power, temperatures, thermal jumps, and airflows in all the situations where we will execute the commissioning tests.
A data center’s availability will depend largely on effective commissioning, and load banks can play an important role in this matter.